Attribute Name -- Attribute Label |
Unit |
Attribute definition |
PHw
--
PH measured in stream/river
|
Unitless |
PH measured in stream/river time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring pH-value with multimeter (Unknown) |
Description
:
|
Measuring pH-value with multimeter (Unknown) |
|
|
ECw
--
electrical conductivity of streamwater
|
Microsiemens per centimeter |
Electrical conductivity of streamwater |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring conductivity with multimeter (Unknown) |
Description
:
|
Measuring conductivity with multimeter (Unknown) |
|
|
Tw
--
water temperature
|
Degrees Celsius |
Water temperature |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Multimeter also has a temperature sensor which was used for obtaining temperature measures |
Description
:
|
Multimeter also has a temperature sensor which was used for obtaining temperature measures |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: null
|
Instrument: Multimeter
|
Vendor: Unknown
|
Measurement:
Measurement type: Conductivity
|
Unit: Microsiemens per centimeter
|
Resolution:
|
Dimension: -
|
Error: -
|
Size: -
|
|
|
|
Cl_w
--
Chloride in stream water
|
Microgram per liter |
Chloride measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Ion chromatography for measuring ions in water |
Description
:
|
Ion chromatography for measuring ions in water |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: units µg/l
|
Instrument: Ion Chromatography
|
Vendor: Dionex
|
Measurement:
Measurement type: Ions
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
NO3_w
--
Nitrate in stream water
|
Microgram per liter |
Nitrate measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Ion chromatography for measuring ions in water |
Description
:
|
Ion chromatography for measuring ions in water |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: units µg/l
|
Instrument: Ion Chromatography
|
Vendor: Dionex
|
Measurement:
Measurement type: Ions
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
SO4_w
--
Sulphate in stream water
|
Microgram per liter |
Sulphate measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Ion chromatography for measuring ions in water |
Description
:
|
Ion chromatography for measuring ions in water |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: units µg/l
|
Instrument: Ion Chromatography
|
Vendor: Dionex
|
Measurement:
Measurement type: Ions
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Li_w
--
Lithium in stream water
|
Microgram per liter |
Lithium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Na_w
--
Sodium in stream water
|
Microgram per liter |
Sodium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Mg_w
--
Magnesium in stream water
|
Microgram per liter |
Magnesium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Al_w
--
Aluminium in stream water
|
Microgram per liter |
Aluminium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Kw
--
Potassium measured in stream/river
|
Milligram per liter |
Potassium measured in stream/river time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Ca_w
--
Calcium in stream water
|
Microgram per liter |
Calcium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
V_w
--
Vanadium in stream water
|
Microgram per liter |
Vanadium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Cr_w
--
Chromium in stream water
|
Microgram per liter |
Chromium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Fe_w
--
Iron in stream water
|
Microgram per liter |
Iron measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Mn_w
--
Manganese in stream water
|
Microgram per liter |
Manganese measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Ni_w
--
Nickel in stream water
|
Microgram per liter |
Nickel measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Cu_w
--
Copper in stream water
|
Microgram per liter |
Copper measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Zn_w
--
Zinc in stream water
|
Microgram per liter |
Zinc measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
As_w
--
Arsenic in stream water
|
Microgram per liter |
Arsenic measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Rb_w
--
Rubidium in stream water
|
Microgram per liter |
Rubidium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Sr_w
--
Strontium in stream water
|
Microgram per liter |
Strontium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Y_w
--
Yttrium in stream water
|
Microgram per liter |
Yttrium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Ba_w
--
Barium in stream water
|
Microgram per liter |
Barium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
La_w
--
Lanthanum in stream water
|
Microgram per liter |
Lanthanum measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Ce_w
--
Cerium in stream water
|
Microgram per liter |
Cerium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Pr_w
--
Praseodymium in stream water
|
Microgram per liter |
Praseodymium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Nd_w
--
Neodymium in stream water
|
Microgram per liter |
Neodymium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Sm_w
--
Samamrium in stream water
|
Microgram per liter |
Samamrium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Gd_w
--
Gadolinium in stream water
|
Microgram per liter |
Gadolinium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Dy_w
--
Dysprosium in stream water
|
Microgram per liter |
Dysprosium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Er_w
--
Erbium in stream water
|
Microgram per liter |
Erbium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Yb_w
--
Ytterbium in stream water
|
Microgram per liter |
Ytterbium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Pb_w
--
Lead in stream water
|
Microgram per liter |
Lead measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
U_w
--
Uranium in stream water
|
Microgram per liter |
Uranium measured in stream water |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
datetime
--
Date and Time
|
not mapped |
The date and time |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Date time (YYYY-MM-DD hh:mm:ss) |
Description
:
|
Date time (YYYY-MM-DD hh:mm:ss) |
|
|