Attribute Name -- Attribute Label |
Unit |
Attribute definition |
Site_name
--
Site name
|
no unit |
Site name |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
RESPECT core plots |
Description
:
|
Predefined RESPECT core plots |
|
|
PlotID
--
ID of the plot
|
no unit |
ID of the plot |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
RESPECT core plots |
Description
:
|
Predefined RESPECT core plots |
|
|
subplot_id
--
ID of the subplot
|
no unit |
ID of the subplot |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Subplot ID of Core Plots |
Description
:
|
Subplot ID of the Core Plots |
|
|
TreeID
--
ID of the tree
|
no unit |
ID of the tree |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Tree ID |
Description
:
|
Tree ID |
|
|
Family
--
Family name
|
no unit |
Scientific family name |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Plant family |
Description
:
|
Plant family |
|
|
Genus
--
Genus name
|
no unit |
Scientific name of genus |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Genus |
Description
:
|
Specifying the genus name |
|
|
Tree_species
--
Tree species
|
no unit |
Tree species |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Identification by comparison with type specimens, identified museum specimens or photos thereof, or by external experts. |
Description
:
|
Identification by comparison with type specimens, identified museum specimens or photos thereof, or by external experts. |
|
|
dry_matter_content
--
Leaf dry matter content
|
Milligram per gram |
Leaf dry matter content |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Leaf dry matter content |
Description
:
|
Dry matter content was determined after fully water-saturated leaves were dried for three days at 60°C. |
|
|
leaf_area
--
leaf area
|
Square centimeter |
total area of leaves calculated in square centimeters |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
WinFolia |
Description
:
|
WinFolia |
|
|
specific_leaf_area
--
Specific leaf area
|
Square centimeters per gram |
the specific leaf area (SLA) in square centimeters per gram |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
leaf area devided by leaf mass |
Description
:
|
total leaf area in squared centimeter per gram of scanned leaves analyzed with the software WinFOLIA (Regent INstruments Inc., Version 2014a, REGULAR VERSION) divided by the total leaf dry mass in gram of the scanned leaf |
|
|
leaf_thickness
--
Leaf thickness
|
Millimeter |
Leaf thickness |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Leaf thickness |
Description
:
|
Leaf thickness measured with a digital micrometer on fresh leaves (excluding the midrib and other major veins). |
|
|
leaf_toughness
--
Leaf toughness
|
force |
Force to punch a leaf using a digital penetrometer (2.0 mm diameter) on fresh leaves (excluding the midrib and other major veins) |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Leaf toughness |
Description
:
|
Force to punch a leaf using a digital penetrometer (2.0 mm diameter) on fresh leaves (excluding the midrib and other major veins) |
|
|
leaf_C
--
Foliar C concentration
|
Milligram per gram |
Foliar C concentration |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
CN analyzer |
Description
:
|
Leaf dry mass was analyzed for its C and N content with a CN analyzer (Vario EL III, Hanau, Germany) |
Instrumentation:
|
Instrument:
Description: CNS analysis with high temperature combustion of organic and inorganic solid samples and detection of the gaseous products with WLD
|
Instrument: CNS-Analyser HERAEUS
|
Vendor: HERAEUS
|
|
|
|
leaf_N
--
Foliar N concentration
|
Milligram per gram |
concentrations of N in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
CN analyzer |
Description
:
|
Leaf dry mass was analyzed for its C and N content with a CN analyzer (Vario EL III, Hanau, Germany) |
Instrumentation:
|
Instrument:
Description: CNS analysis with high temperature combustion of organic and inorganic solid samples and detection of the gaseous products with WLD
|
Instrument: CNS-Analyser HERAEUS
|
Vendor: HERAEUS
|
|
|
|
CN_ratio
--
C/N ratio
|
Ratio |
Carbon/Nitrogen ratio |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Calculated |
Description
:
|
Calculated |
|
|
leaf_Al
--
Foliar Al concentration
|
Milligram per gram |
Concentrations of Al in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|
leaf_Ca
--
Foliar Ca concentration
|
Milligram per gram |
Concentrations of Ca in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|
leaf_Fe
--
Foliar Fe concentration
|
Milligram per gram |
Concentrations of Fe in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|
leaf_K
--
Foliar K concentration
|
Milligram per gram |
Concentrations of K in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|
leaf_Mg
--
Foliar Mg concentration
|
Milligram per gram |
Concentrations of Mg in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|
leaf_Mn
--
Foliar Mn concentration
|
Milligram per gram |
Concentrations of Mn in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|
leaf_P
--
Foliar P concentration
|
Milligram per gram |
concentrations of P in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|
leaf_S
--
Foliar S concentration
|
Milligram per gram |
Concentrations of S in foliar tissue |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Determine foliar nutrient concentration with Inductively Coupled Plasma Analyzer |
Description
:
|
Foliar nutrient concentration was determined with an Inductively Coupled Plasma Analyzer (Thermo Fisher Scientific) after digesting the ground leaf material with concentrated HNO3 |
Instrumentation:
|
Instrument:
Description:
|
Instrument: Inductively Coupled Plasma Analyzer
|
Vendor: Thermo Fisher Scientific
|
|
|
|