Attribute Name -- Attribute Label |
Unit |
Attribute definition |
PHw_pcp
--
PH measured in precipitation
|
Unitless |
PH measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring pH-value with multimeter (Unknown) |
Description
:
|
Measuring pH-value with multimeter (Unknown) |
|
|
ECw_pcp
--
Electrical conductivity measured in precipitation
|
Microsiemens per centimeter |
Electrical conductivity measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring conductivity with multimeter (Unknown) |
Description
:
|
Measuring conductivity with multimeter (Unknown) |
|
|
Naw_pcp
--
Sodium measured in precipitation
|
Milligram per liter |
Sodium measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Mgw_pcp
--
Magnesium measured in precipitation
|
Milligram per liter |
Magnesium measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
NO3w_pcp
--
Nitrate measured in precipitation
|
Milligram of nitrogen per liter |
Nitrate measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Ion chromatography for measuring ions in water |
Description
:
|
Ion chromatography for measuring ions in water |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: units µg/l
|
Instrument: Ion Chromatography
|
Vendor: Dionex
|
Measurement:
Measurement type: Ions
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Stotw_pcp
--
Total sulphur measured in precipitation
|
Milligram per liter |
Total sulphur measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Ion chromatography for measuring ions in water |
Description
:
|
Ion chromatography for measuring ions in water |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: units µg/l
|
Instrument: Ion Chromatography
|
Vendor: Dionex
|
Measurement:
Measurement type: Ions
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Caw_pcp
--
Calcium measured in precipitation
|
Milligram per liter |
Calcium measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
Kw_pcp
--
Potassium measured in precipitation
|
Milligram per liter |
Potassium measured in precipitation time series |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Description
:
|
Measuring elements in water with inductively coupled plasma mass spectrometry |
Instrumentation:
|
measurementheight=0.0
Instrument:
Description: concentrations are all in ppb, i.e. in µg/l
|
Instrument: ICP-MS
|
Vendor: Agilent Technologies
|
Measurement:
Measurement type: elements
|
Unit: Microgram per liter
|
Resolution: 0.0
|
Dimension: 0
|
Error: 0.0
|
Size:
|
|
|
|
datetime
--
Date and Time
|
not mapped |
The date and time |
Method
(Sampling/processing description of the values of
this attribute by one ore more steps.)
|
--- Step
1
---
|
Title
:
|
Date time (YYYY-MM-DD hh:mm:ss) |
Description
:
|
Date time (YYYY-MM-DD hh:mm:ss) |
|
|