Platform data



  1. 1
Search results for: "keyword:"caldern""

Overview

1-6 of 6 datasets.

(Click for the detailed view)



Detailed view

Dendrometer measurements of changes in tree width and sapflow on tree 3 in Caldern
Dataset ID: 360
Last updated: 2024-07-24
Dataset creators: Maik Dobbermann
Contact: Maik Dobbermann
Boris Thies
Temporal coverage: 2017-12-04 19:00:00 - 2024-07-24 07:30:00 - time zone: Europe/Berlin
Geographic coverage: Caldern Klima-Messturm Wald
Abstract: ---
Additional info: ---
Keywords: | caldern | dendrometer |
Intellectual rights: LCRS
Entity name: combined_dendro_out.csv.csv_treeid3_readytoupload
Entity type:dataTable
Attributes:
Date and Time (datetime) (Unitless)
Record number (record) [Count]
ID of the tree (TreeID) (Unitless)
Mechanical resistance in ohm (resistance_ohm) [Ohm]
Better granier based Sap Flow Data (raw) (left needle) (sap_flow_raw_SF-L_left) [Millivolt]
Better granier based Sap Flow Data (raw) (sap_flow_raw_SF-L_center) [Millivolt]
Better granier based Sap Flow Data (raw) (right needle) (sap_flow_raw_SF-L_right) [Millivolt]

Dendrometer measurements of changes in tree width and sapflow on tree 1 in Caldern
Dataset ID: 348
Last updated: 2024-07-24
Dataset creators: Boris Thies
Maik Dobbermann
Contact: Boris Thies
Temporal coverage: 2017-12-04 19:00:00 - 2024-07-24 07:30:00 - time zone: Europe/Berlin
Geographic coverage: Caldern Klima-Messturm Wald
Abstract: ---
Additional info: ---
Keywords: | Trees | caldern | sap flow | dendrometer |
Intellectual rights: LCRS
Entity name: tree width grows and sapflow in caldern measured for tree 1
Entity type:dataTable
Attributes:
Date and Time (datetime) (Unitless)
Record number (record) [Count]
ID of the tree (TreeID) (Unitless)
Mechanical resistance in ohm (resistance_ohm) [Ohm]
Better granier based Sap Flow Data (raw) (left needle) (sap_flow_raw_SF-L_left) [Millivolt]
Better granier based Sap Flow Data (raw) (sap_flow_raw_SF-L_center) [Millivolt]
Better granier based Sap Flow Data (raw) (right needle) (sap_flow_raw_SF-L_right) [Millivolt]

Caldern Klimastation Wiese
Dataset ID: 302
Last updated: 2024-07-24
Dataset creators: Sebastian Achilles
Boris Thies
Maik Dobbermann
Contact: Maik Dobbermann
Boris Thies
Sebastian Achilles
Temporal coverage: 2017-06-29 11:45:00 - 2024-07-24 00:00:00 - time zone: Atlantic/Reykjavik
Geographic coverage: Caldern Klima-Messturm Wiese
Abstract: ---
Additional info: ---
Keywords: | caldern | klimastation |
Intellectual rights: LCRS
Entity name: Klimaturm Caldern Wiese
Entity type:dataTable
Attributes:
Date and Time (datetime) (Unitless)
Record number (record) [Count]
Battery voltage (BattV) [Volt]
Temperature in control cabinet (PTemp_C) [Degrees Celsius]
air temperature in 2m (Ta_2m) [Degrees Celsius]
Air humidity 2m (Huma_2m) [Percent]
Air temperature in 10m height (Ta_10m) [Degrees Celsius]
Relative air humidity in 10 meter height (Huma_10m) [Percent]
Incoming Shortwave Radiation (rad_sw_in) [Watt per square meter]
Outgoing Shortwave Radiation (rad_sw_out) [Watt per square meter]
Incoming Longwave Radiation (rad_lw_in) [Watt per square meter]
Outgoing Longwave Radiation (rad_lw_out) [Watt per square meter]
Temperature of the radiation measuring instrument (CNR4TC) [Degrees Celsius]
Temperature of the radiation measuring instrument in Kelvin (CNR4TK) [Degree Kelvin]
short-wave radiation balance (RsNet) [Watt per square meter]
long-wave radiation balance, temperature corrected (RlNet) [Watt per square meter]
Albedo (Albedo) [Percent]
Radiation Balance (rad_net) [Watts per square meter per Watts per square meter ]
temperature corrected incoming long-wave radiation (LUpCo) [Watt per square meter]
temperature corrected outgoing long-wave radiation (LDnCo) [Watt per square meter]
volumic soil water content (water_vol_soil) [cubic meter per cubic meter]
Electric conductivity (EC) [Square meter per square meter]
Soil temperature (Ts) [Degrees Celsius]
Internal parameter to calculate soil water content and electric conductivity (P) [Unitless]
Internal parameter to calculate soil water content and electric conductivity (PA) [Unitless]
Internal parameter to calculate soil water content and electric conductivity (VR) [Unitless]
Soil heat flux (heatflux_soil) [Watt per square meter]
Wind speed in 2 meters height (Windspeed_2m) [Meter per second]
Wind direction in 3 meters height (Wind_direction_3m) [Degree]
Internal flag for diagnosing windsonic (WSDiag_1) (Unitless)
Wind speed in 10 meters height (Windspeed_10m) [Meter per second]
Wind direction in 10 meters height (Wind_direction_10m) [Degree]
Internal flag for diagnosing windsonic (WSDiag_2) (Unitless)
precipitation (PCP) [Millimeter]
Entity name: 20181101_protocol_caldern_wiese.csv_upload
Entity type:dataTable
Attributes:
Section (Section) (Unitless)
SectionSubsection (Subsection) (Unitless)
Question (Question) (Unitless)
Answer (Answer) (Unitless)
Explain (Explain) (Unitless)
Action taken (Action_taken) (Unitless)
Comment (Comment) (Unitless)
Datetime of specific event (eventdatetime) (Unitless)
Person who inspects (inspector) (Unitless)
Name of site (sitename) (Unitless)

Dendrometer measurements of changes in tree width and sapflow on tree 2 in Caldern
Dataset ID: 359
Last updated: 2024-07-24
Dataset creators: Maik Dobbermann
Contact: Maik Dobbermann
Boris Thies
Temporal coverage: 2017-12-04 19:00:00 - 2024-07-24 07:30:00 - time zone: Europe/Berlin
Geographic coverage: Caldern Klima-Messturm Wald
Abstract: ---
Additional info: ---
Keywords: | caldern | dendrometer |
Intellectual rights: LCRS
Entity name: combined_dendro_out.csv.csv_treeid2_readytoupload
Entity type:dataTable
Attributes:
Date and Time (datetime) (Unitless)
Record number (record) [Count]
ID of the tree (TreeID) (Unitless)
Mechanical resistance in ohm (resistance_ohm) [Ohm]
Better granier based Sap Flow Data (raw) (left needle) (sap_flow_raw_SF-L_left) [Millivolt]
Better granier based Sap Flow Data (raw) (sap_flow_raw_SF-L_center) [Millivolt]
Better granier based Sap Flow Data (raw) (right needle) (sap_flow_raw_SF-L_right) [Millivolt]

Caldern Klimastation Wald
Dataset ID: 301
Last updated: 2024-07-24
Dataset creators: Sebastian Achilles
Boris Thies
Maik Dobbermann
Contact: Maik Dobbermann
Boris Thies
Sebastian Achilles
Temporal coverage: 2017-07-05 11:05:00 - 2024-07-24 07:30:00 - time zone: Atlantic/Reykjavik
Geographic coverage: Caldern Klima-Messturm Wald
Abstract: ---
Additional info: Kontinuierlich erweiterter Datensatz mit auf 5 Min...
Keywords: | Klima | caldern | klimastation |
Intellectual rights: LCRS
Entity name: wald_sorted_converted_wpcp
Entity type:dataTable
Attributes:
Date and Time (datetime) (Unitless)
Record number (record) [Count]
Battery voltage (BattV) [Volt]
Temperature in control cabinet (PTemp_C) [Degrees Celsius]
air temperature in 2m (Ta_2m) [Degrees Celsius]
Air humidity 2m (Huma_2m) [Percent]
Air temperature in 10m height (Ta_10m) [Degrees Celsius]
Relative air humidity in 10 meter height (Huma_10m) [Percent]
Incoming Shortwave Radiation (rad_sw_in) [Watt per square meter]
Outgoing Shortwave Radiation (rad_sw_out) [Watt per square meter]
Incoming Longwave Radiation (rad_lw_in) [Watt per square meter]
Outgoing Longwave Radiation (rad_lw_out) [Watt per square meter]
Temperature of the radiation measuring instrument (CNR4TC) [Degrees Celsius]
Temperature of the radiation measuring instrument in Kelvin (CNR4TK) [Degree Kelvin]
short-wave radiation balance (RsNet) [Watt per square meter]
long-wave radiation balance, temperature corrected (RlNet) [Watt per square meter]
Albedo (Albedo) [Percent]
Radiation Balance (rad_net) [Watts per square meter per Watts per square meter ]
temperature corrected incoming long-wave radiation (LUpCo) [Watt per square meter]
temperature corrected outgoing long-wave radiation (LDnCo) [Watt per square meter]
volumic soil water content (water_vol_soil) [cubic meter per cubic meter]
Electric conductivity (EC) [Square meter per square meter]
Soil temperature (Ts) [Degrees Celsius]
Internal parameter to calculate soil water content and electric conductivity (P) [Unitless]
Internal parameter to calculate soil water content and electric conductivity (PA) [Unitless]
Internal parameter to calculate soil water content and electric conductivity (VR) [Unitless]
Soil heat flux (heatflux_soil) [Watt per square meter]
Wind speed in 2 meters height (Windspeed_2m) [Meter per second]
Wind direction in 3 meters height (Wind_direction_3m) [Degree]
Internal flag for diagnosing windsonic (WSDiag_1) (Unitless)
Wind speed in 10 meters height (Windspeed_10m) [Meter per second]
Wind direction in 10 meters height (Wind_direction_10m) [Degree]
Internal flag for diagnosing windsonic (WSDiag_2) (Unitless)
precipitation (PCP) [Millimeter]
Entity name: 20181001_protocol_caldern_wald.csv_upload
Entity type:dataTable
Attributes:
Section (Section) (Unitless)
SectionSubsection (Subsection) (Unitless)
Question (Question) (Unitless)
Answer (Answer) (Unitless)
Explain (Explain) (Unitless)
Action taken (Action_taken) (Unitless)
Comment (Comment) (Unitless)
Datetime of specific event (eventdatetime) (Unitless)
Person who inspects (inspector) (Unitless)
Name of site (sitename) (Unitless)

Caldern Klimastation Eddy Covariance
Dataset ID: 535
Last updated: 2024-07-26
Dataset creators: Sebastian Achilles
Maik Dobbermann
Contact: Maik Dobbermann
Sebastian Achilles
Temporal coverage: 2021-07-13 11:25:00 - 2024-07-24 07:50:00 - time zone: Europe/Berlin
Geographic coverage: Caldern Klima-Messturm Wiese
Abstract: ---
Additional info: ---
Keywords: | Climate | caldern | AWS | campbell |
Intellectual rights: LCRS
Entity name: toa5_9485.data.dat_out
Entity type:dataTable
Attributes:
Date and Time (datetime) (Unitless)
Record number (record) [Count]
Battery voltage (BattV) [Volt]
Temperature in control cabinet (PTemp_C) [Degrees Celsius]
Datalogger Temperature Max (PTemp_C_Max) [Degrees Celsius]
Average air temperature (AirTC_Avg) [Degrees Celsius]
Relative humidity average (RH) [Percent]
shortwave up (CM3Up_Avg) [Watt per square meter]
shortwave down (CM3Dn_Avg) [Watt per square meter]
longwave up (CG3Up_Avg) [Watt per square meter]
longwave down (CG3Dn_Avg) [Watt per square meter]
casetemp radiation (CNR1TC_Avg) [Degrees Celsius]
Radiometer Temperature (case temp) (CNR1TK_Avg) [Degree Kelvin]
Shortware Net Radiation (NetRs_Avg) [Watt per square meter]
Infrared Net Radiation (NetRl_Avg) [Watt per square meter]
Albedo (Albedo_Avg) [Percent]
Incoming Total Radiation (UpTot_Avg) [Watt per square meter]
Outgoing Total Radiation (DnTot_Avg) [Watt per square meter]
Total Net Radiation (NetTot_Avg) [Watt per square meter]
Incoming Temperature Corrected Infrared Radiation (CG3upCo_Avg) [Watt per square meter]
Outgoing Temperature Corrected Infrared Radiation (CG3DnCo_Avg) [Watt per square meter]
Volumetric water content (Vwc) [Count]
Electric conductivity (EC) [Square meter per square meter]
Soil temperature (Ts) [Degrees Celsius]
Soil Permittivity (SPer) [Unitless]
Period (VD) [Unitless]
Internal parameter to calculate soil water content and electric conductivity (VR) [Unitless]
Rain total (PCP_tot_bucket) [Millimeter]
Soil Heat Flux Plate (HFP) [Watt per square meter]


  1. 1