Due to technical problems the former weather station ECSF (established 1998) was shut down in 2010. At the same time a new weather station called "Climate Station ECSF established 2010" was installed 3m beside the former ECSF weather station on the same measuring plot.
The data are quality checked by a standardised method.
Climate Parameter Quality Check for site ECSF
Checking modules:
1. Does a value exist?
Quality flag is set to
"d = missing"
2. Checking of site specific threshold value.
If the value is not inbetween the thresholds the quality flag is set to "c = out of range":
Windspeed max = 25
Global Radiation max = 1400
Air temperature in 2m max = 30
Air temperature in 2m min = 5
Air humidity max = 99.9
Air humidity min = 10
3. Checking the plausibility of air temperature and air humidity within the measurement intervals by comparing the previous and current values.
If the temperature amplitude is higher then 10°C and humidity amplitude is higher than 30% the plausibility of this variation is checked by comparing to the variation of the other parameter.
The quality flag is set to "e = variation implausible".
4. Precipitation check
If precipitation is more than 25 mm then quality flag is set to "c = out of range"
If precipitation is more than 15 mm and air temperature increases more than 0.2 °C inbetween a temporal interval then quality flag is set to "e = variation impossible".
5. Relative air humidity values are corrected by a standarized method and quality flag is set to "m = manually corrected".
6. Wind direction is not quality checked and flag is set to "nqc = not quality checked"
All other values are set to "a = valid".